Gas conversion factors
To determine corrected flowrate: find the gas for which the meter is calibrated in the left column, move to the right to the gas that is being used. Multiply the flowrate indicated on the meter by the correction factor. This will equal an approximation of the flowrate of the gas being used. Please note: this correction factor is only accurate within ±10%
Gas being used / S.G.
Gas for which
meter is calibrated
H2 He Cracked Ammonia Methane Ammonia City Gas Neon Acetylene N2 or CO Air Ethane O2 Argon CO2 or N2O Propane Butane
0.070 0.138 0.294 0.554 0.588 0.620 0.700 0.899 0.967 1.000 1.038 1.105 1.379 1.520 1.523 2.007
Air 3.78 2.69 1.84 1.34 1.30 1.27 1.20 1.05 1.02 1 0.98 0.95 0.85 0.81 0.81 0.71
Oxygen 3.97 2.83 1.94 1.41 1.37 1.34 1.26 1.11 1.07 1.05 1.03 1 0.90 0.85 0.85 0.74
Calculating Conversion Factors
Based on Specific Gravity
Products | Corporate Profile | Contact Us | Custom Engineered Products | Customer Survey
Spanish/Espanol | German/Deutsch

Copyright 2004 www.keyinstruments.com